EO556-IO is the stepper drive that the control mode is IO control,which through its internal built-in emitter to send pulse to control the motor rotate,and the DIPs to control the speed.

Product Introduction
Equipped with professional 2 Phase Stepper Motor Controller factory, It is a leading stepper motor controller io control mode manufacturer and supplier.

 

Product Electrical Specifications 

 

Item

EO556-IO

Value MIN

Typical Value

Value MAX

UNIT

Output Current

0.1

-

5.6

A

Input Voltage

24

36

50

VDC

Control Signal Input Current

6

10

16

mA

Control Signal interface level

4.5

5

28

Vdc

Input signal Min Pulse Width

1.5

-

-

us

Speed Range

1

-

1000

RPM

Resistor

500

 

 

 

Product Diagram

io 556

 

Product Features

 

●New 32-bit DSP technology

●Ultra low vibration noise

●Built-in micro-step subdivision function

●Parameter power-on auto-tuning function

The variable current control greatly reduces the heating of the motor

●The current is automatically halved when stationary

Can drive 4, 6, 8 wire two-phase stepper motors

●Optically isolated differential signal input

●The current setting is convenient and can be arbitrarily selected between 0.1-5.6A

●Speed setting range is 1-1000RPM

●With overvoltage, under-voltage, overcurrent and other protection functions

 

Product Dimension(Unit:mm)

 

io 556 d

 

Current Setting

Output Peak Current

Output AVG Current

SW1

SW2

SW3

Current Self-Setting

Default[1.0A]

OFF

OFF

OFF

When SW1, SW2 and SW3 are set to OFF, the required current can be set by PC software, the maximum value is 5.6A, and the resolution is 0.1A. If not set, the default current is 1.4A.

2.1A

1.5A

ON

OFF

OFF

2.7A

1.9A

OFF

ON

OFF

3.2A

2.3A

ON

ON

OFF

3.8A

2.7A

OFF

OFF

ON

4.3A

3.1A

ON

OFF

ON

4.9A

3.5A

OFF

ON

ON

5.6A

4.0A

ON

ON

ON

Note: The quiescent current can be set by the SW4 DIP switch, OFF means that the quiescent current is set to half of the dynamic current, and ON means that the quiescent current is the same as the dynamic current. In general use, SW4 should be set to OFF, so that the heat generation of the motor and the driver is reduced and the reliability is improved. About 400ms after the pulse train stops, the current is automatically reduced to about half (60% of the actual value), and the calorific value is theoretically reduced to 30%.

 

Internal self-transmit Pulse Speed Setting

 

RPM

SW5

SW6

SW7

SW8

Subdivision Description

Default[40]

ON

ON

ON

ON

When SW5, SW6, SW7, SW8 are all on, the internal speed of the drive is set by the user through the PC software ProTuner or STU debugger, the minimum value is 1, the resolution is 1, and the maximum value is 1000RPM。

50

OFF

ON

ON

ON

60

ON

OFF

ON

ON

70

OFF

OFF

ON

ON

80

ON

ON

OFF

ON

90

OFF

ON

OFF

ON

100

ON

OFF

OFF

ON

150

OFF

OFF

OFF

ON

200

ON

ON

ON

OFF

250

OFF

ON

ON

OFF

350

ON

OFF

ON

OFF

450

OFF

OFF

ON

OFF

550

ON

ON

OFF

OFF

650

OFF

ON

OFF

OFF

750

ON

OFF

OFF

OFF

850

OFF

OFF

OFF

OFF

 