Product Electrical Specification
|
Item |
EO556-AI |
|||
|
Minimum Value |
|
Minimum Value |
|
|
|
Continuous output current |
0.4 |
Continuous output current |
0.4 |
Continuous output current |
|
Power Supply Voltage (DC) |
20 |
Power Supply Voltage (DC) |
20 |
Power Supply Voltage (DC) |
|
Control signal input current |
6 |
Control signal input current |
6 |
Control signal input current |
|
Control signal interface level |
5 |
Control signal interface level |
5 |
Control signal interface level |
|
OC output pull-up voltage |
5 |
OC output pull-up voltage |
5 |
OC output pull-up voltage |
|
Insulation Resistance |
- |
Insulation Resistance |
- |
Insulation Resistance |
Product Features
1.New 32 Bit DSP Technology
2.Dial code can be set to pulse control, IO spontaneous pulse control, 0-10V analog speed control
3.It is able to select up or down edge, single or double pulse
4.Low filtering time (high response) or high filtering time (low vibration) can be selected by dial
5.1-way 0-10V analog input
6.Automatic parameter power-on setting function
7.Variable current control greatly reduces the heat generation of the motor.
8.Automatic halving of current at rest
9.Can drive a variety of stepping motor ,such as 28,42,57,60
10.Three optical isolation signal inputs, two of which are high-speed opto-coupler isolation
11.1 way alarm output, photoelectric isolation OC emitter output
12.The current setting is convenient and can be selected between 0.4-5.6 A
13.It has the protection functions of over-voltage, under-voltage and over-current.
Product Diagram

Product Current Setting
|
Peak |
RMS |
SW1 |
SW2 |
SW3 |
SW4 |
|
0.4A |
0.3A |
on |
on |
on |
on |
|
0.7A |
0.5A |
off |
on |
on |
on |
|
1.0A |
0.7A |
on |
off |
on |
on |
|
1.1A |
0.8A |
off |
off |
on |
on |
|
1.4A |
1.0A |
on |
on |
off |
on |
|
1.7A |
1.2A |
off |
on |
off |
on |
|
2.1A |
1.5A |
on |
off |
off |
on |
|
2.5A |
1.8A |
off |
off |
off |
on |
|
2.8A |
2.0 A |
on |
on |
on |
off |
|
3.0A |
2.2A |
off |
on |
on |
off |
|
3.8A |
2.7A |
on |
off |
on |
off |
|
4.2A |
3.0A |
off |
off |
on |
off |
|
4.5A |
3.2A |
on |
on |
off |
off |
|
4.9A |
3.5A |
off |
on |
off |
off |
|
5.3A |
3.8A |
on |
off |
off |
off |
|
5.6A |
4.0A |
off |
off |
off |
off |
Note: Above format current is the standard EO556-AI current, other current can be derived according to customer demand, can set the current range between 0.3-5.6 A.
Product Subdivision Setting
Dialing sets the subdivision and it-self spontaneous pulses
|
Pul/Rev |
S5 |
S6 |
S7 |
S8 |
Remark |
|
200 |
on |
on |
on |
on |
When SW5、SW6、SW7、SW8 all are ON,the driver subdivision of driver is the internal default subdivision,and can be the value of subdivision which customer need |
|
400 |
off |
on |
on |
on |
|
|
800 |
on |
off |
on |
on |
|
|
1600 |
off |
off |
on |
on |
|
|
3200 |
on |
on |
off |
on |
|
|
6400 |
off |
on |
off |
on |
|
|
12800 |
on |
off |
off |
on |
|
|
25600 |
off |
off |
off |
on |
|
|
1000 |
on |
on |
on |
off |
|
|
2000 |
off |
on |
on |
off |
|
|
4000 |
on |
off |
on |
off |
|
|
5000 |
off |
off |
on |
off |
|
|
8000 |
on |
on |
off |
off |
|
|
10000 |
off |
on |
off |
off |
|
|
20000 |
on |
off |
off |
off |
|
|
25000 |
off |
off |
off |
off |
IO/AI Speed Setting(Internal generate pulse or 0-10V analog speed control setting)
|
RPM/MIN |
S5 |
S6 |
S7 |
S8 |
Speed Explanation |
|
40 |
on |
on |
on |
on |
When SW5、SW6、SW7、SW8all are ON,the driver speed applys its internal default speed: can derive the speed that customer need |
|
50 |
off |
on |
on |
on |
|
|
60 |
on |
off |
on |
on |
|
|
70 |
off |
off |
on |
on |
|
|
80 |
on |
on |
off |
on |
|
|
90 |
off |
on |
off |
on |
|
|
100 |
on |
off |
off |
on |
|
|
150 |
off |
off |
off |
on |
|
|
200 |
on |
on |
on |
off |
|
|
250 |
off |
on |
on |
off |
|
|
350 |
on |
off |
on |
off |
|
|
450 |
off |
off |
on |
off |
|
|
550 |
on |
on |
off |
off |
|
|
650 |
off |
on |
off |
off |
|
|
750 |
on |
off |
off |
off |
|
|
850 |
off |
off |
off |
off |
Note: 1, Above format subdivision are the standard product EO556-AI subdivisions, other subdivisions can be derived according to customer needs, can set the value between 200-51200 , subdivide table refer to [ Pulse/rev ] this column table.
2, when the drive is set to IO control or analog control mode by dialing SW15 and SW16, the corresponding speed refer to [ IO/AI (RPM)] this column speed table.
Product Dimension(UNIT:mm)

Hot Tags: analog speed control stepper driver eo556-ai, manufacturer, supplier, factory